Lutron RA2 Select In-Line Dimmer

$395.00

View All Lutron

In Stock, Available Now

Enquire

Details

Specifications

Automated lighting control

The RA2 Select family of in-line dimmers and switches can control lighting and motor loads both locally and remotely when paired with Pico wireless controls or Radio Powr Savr occupancy/vacancy sensors. This provides a system that is convenient and easy to install.

RA2 Select in-line load controls use Lutron patented Clear Connect RF technology which provides reliable, wireless communication with other RA2 Select devices. Each load control can be controlled individually using a Pico wireless control. Using an RA2 Select main repeater allows devices to be part of a whole house solution that can be controlled remotely from anywhere in the world.

  • Small size allows for simple retrofit installation.
  • Allows remote control from anywhere in the space when paired with Pico wireless controls.
  • Capable of 1A load and up to 150W of LED, or 250W of incandescent, halogen, or ELV loads
  • Power: 220–240 V~ 50/60 Hz
  • Typical Power Consumption: < 0.5 W (Test conditions: Load and LED are off)
  • Load types: 1A 250W incandescent, halogen, ELV; 1A 250W LED (the LEDs have to be lutron compatible)
  • Regulatory Approvals: CE
  • Dimensions: 46mm width, 153mm length, 32mm height. 
  • Environment: Ambient operating temperature: 0 °C to 40 °C (32 °F to 104 °F), 0% to 90% humidity, non-condensing. Indoor use only.
  • Communications: RA2 Select in-line load controls communicate with the system through Radio Frequency (RF). They must be located within 18 m (60 ft) line-of-sight or 9 m (30 ft) through walls of a Pico wireless control, Radio Powr Savr sensor, or RA2 Select repeater. System devices operate at 868 MHz.
  • ESD Protection: Tested to withstand electrostatic discharge without damage or memory loss, in accordance with IEC 61000-4-2.
  • Surge Protection: Tested to withstand surge voltages without damage or loss of operation, in accordance with IEEE C62.41-1991 Recommended Practice for Surge Voltages in Low-Voltage AC Power Circuits.
  • Power failure memory: should power be interrupted, the control will return to its previously set level prior to the interruption when power is restored.
  • Mounting: Allow adequate space to ensure convective cooling of load control. Remove any insulation, heat generating equipment, or obstructions within 120 mm (4.75 in) of the load control. For optimal RF performance, no metal or other electrically conductive material should be present within 120 mm (4.7 in) around the top and sides of the load control. The load control is not suitable for installation in places where it is fully enclosed in metal (e.g., metal enclosures, electrical cabinets) or within metal ceilings.
  • Wiring: RA2 Select in-line controls accept wire gauges between 0.5 mm2 to 2.5 mm2 (20 AWG to 14 AWG).
    Note: All outside wire diameters must be the same and must be between 5.2 mm–8.5 mm (0.2 in–0.3 in).
  • Device Limits: Up to 100 devices (e.g., load controls, Pico wireless controls, Radio Powr Savr sensors, shades, and repeaters) are supported per system. The main repeater counts as one device and four locations are reserved for wireless repeaters.
    Note: Load controls have load type and capacity limits

Due to the bespoke nature of our high-end music systems this product is not available to be purchased online. Please contact us for personalized service from one of our team of experts.